A basement bedroom in Tacoma needs an emergency escape and rescue opening, usually an egress window with at least 5.7 square feet of clear opening (5 square feet at grade floor), at least 24 inches high and 20 inches wide, with a sill no higher than 44 inches. Turning a basement into an ADU also requires construction permits.
This guide covers the egress rules in the 2021 International Residential Code as adopted in Washington, and the City of Tacoma’s accessory dwelling unit (ADU) rules as of November 2026. Confirm your plans with the city before you build.
Does a Basement Bedroom Need an Egress Window?
Yes. Washington’s residential code requires basements, habitable attics and every sleeping room to have at least one operable emergency escape and rescue opening. When a basement has sleeping rooms, each sleeping room needs its own. The opening must lead to a public way, or to a yard or court at least 36 inches wide that opens to one.
There is one exception: if the home has an automatic sprinkler system, basement sleeping rooms don’t need their own escape openings, as long as the basement has either one code-compliant exit plus one escape opening, or two code-compliant exits.
What Size Does a Basement Egress Window Have to Be?
- Net clear opening: at least 5.7 square feet. Openings at grade floor (within 44 inches of the outside grade) can be 5 square feet.
- Height: at least 24 inches of clear opening.
- Width: at least 20 inches of clear opening.
- Sill height: the bottom of the clear opening no more than 44 inches above the floor.
- Easy to open: operable from inside without keys, tools or special knowledge.
A 20-by-24-inch opening meets the height and width minimums but not the area minimum, so the window has to satisfy all of these at once.
What Are the Window Well Requirements?
- A window well (area well) is required when the bottom of the opening is below the ground outside.
- It must be at least 9 square feet, with at least 36 inches of projection and width, and let the window open fully.
- Wells deeper than 44 inches need a permanently attached ladder or steps.
- Wells need proper drainage, usually tied into the foundation drain.
What About Ceiling Height and Room Size?
Minimum ceiling heights and minimum room dimensions apply to habitable basement rooms. Tacoma lists both, along with bedroom emergency escape and smoke and carbon monoxide alarms, among the code items an ADU must meet. Beams, ducts and pipes can lower the effective height, so measure early and confirm the requirement for your room with the city’s Residential Review team before you design around it.
Can I Turn My Basement into an ADU in Tacoma?
Yes. In Tacoma’s Urban Residential zones, ADUs can be inside or attached to the main house, or detached. Key rules from the city:
- Two attached and/or detached ADUs are allowed on any legally established lot. Adding two attached ADUs to an existing single-unit home makes it a triplex under the International Building Code.
- An ADU’s habitable area is limited to 1,000 square feet, not counting garages and other non-living areas.
- Each ADU needs facilities for cooking, living, sanitation and sleeping, and its own visible address.
- Attached ADUs need interconnected smoke and carbon monoxide alarms, and each unit needs access to control its own heating and water heater.
- No off-street parking is required for an ADU.
- The city’s ADU page sets no general owner-occupancy rule, but using either unit as a short-term rental requires the owner to occupy one of them.
- Owner-occupants earning no more than 150% of the Pierce County family median income can qualify for some flexible standards.
What Permits Do I Need for a Basement ADU?
Tacoma requires construction permits to create, convert or legalize an ADU. Depending on the project, that can include building, plumbing, mechanical, electrical, side sewer and other permits. The city recommends scheduling an appointment with staff first to review requirements. Permits must be issued before work starts; the city warns that starting early will likely mean double fees and opening up work to verify it.
Contact Tacoma Planning and Development Services at (253) 591-5030, [email protected], or TacomaPermits.org. Homes outside Tacoma city limits follow Pierce County’s or their own city’s rules.
Frequently Asked Questions
Can a basement room without a window be a bedroom?
Not without an emergency escape and rescue opening, unless the home qualifies for the sprinkler exception described above.
Do I need a permit to finish my basement in Tacoma?
Finish work like paint, carpet and tile is exempt, but building new walls, adding plumbing or ductwork, or creating an ADU needs permits. See our Tacoma permit guide.
Does a basement ADU need its own entrance?
The city requires a walkway to the nearest public sidewalk for ADUs with a separate exterior entrance. Confirm entrance and exit requirements for your layout with the city.
Plan Your Basement Project
See our basement remodeling in Tacoma, or contact us or call (253) 461-1499 for a free quote.
Related reading: Creating a Legal ADU · Basement Remodeling: Guest Suite Transformation
Sources
- Accessory Dwelling Units (City of Tacoma)
- Accessory Dwelling Units in UR Districts tip sheet (City of Tacoma, February 2025)
- WAC 51-51-03100: Emergency escape and rescue openings (Washington’s amendments to IRC R310)
- Emergency escape and rescue openings, 2021 IRC Section R310 (City of Aberdeen Building Department)
- 2021 IRC significant changes (City of Lake Stevens)